Position: HOME > Product > Water purification equipment > Water Filter Element >
LF BW 4040 Reverse Osmosis Membrane Element 2600 GPD 99.6 Percent Desalination For Small Water Plant And Boiler Make Up Water
  • LF BW 4040 Reverse Osmosis Membrane Element 2600 GPD 99.6 Percent Desalination For Small Water Plant And Boiler Make Up Water

LF BW 4040 Reverse Osmosis Membrane Element 2600 GPD 99.6 Percent Desalination For Small Water Plant And Boiler Make Up Water

Read 1 Reviews23 Q&As Write a Review
LF-BW-4040 reverse osmosis membrane element gives 2600 GPD average water production with 99.6% stable desalination rate on a 100 ft² area, built for small water plants, boiler make-up and food beverage lines.

PARAMETER

Brand Name: None
Model Number: LF-BW-4040
Nominal filtration rating:脱盐率 99.6%(稳定)/ 99.0%(最低)
Application:小型纯净水站、锅炉补给水、食品饮料用水
Operating pressure:
Working temperature: 0-45℃
Replacement or not:Replacement

Product Overview

Water Filter Element covers consumables and complete membrane systems, and the BW 4040 RO membrane is the 4 inch low-pressure aromatic polyamide composite element in that range. It is designed for desalination of brackish water, surface water, groundwater and tap water with moderate salt content, and also serves wastewater reuse and concentration duties. Rated membrane area 100 ft² (9.3 m²), average water production 2600 GPD (9.8 m³/d), stable desalination rate 99.6%, minimum 99.0%, tested at 225 psi with 2000 mg/L NaCl solution.

Basic Technical Parameters

ModelLF-BW-4040
Membrane area100 ft² (9.3 m²)
Average water production2600 GPD (9.8 m³/d)
Stable desalination rate99.6%
Minimum desalination rate99.0%
Test pressure / solution225 psi (1.55 MPa) / 2000 mg/L NaCl at 25 ℃
Single element recovery15%
Maximum operating pressure600 psi (4.14 MPa)
Maximum inflow rate3.6 m³/h
Inlet water temperature0-45 ℃
Maximum inflow SDI155.0
Inlet free chlorineLess than 0.1 mg/L
pH range (operation / cleaning)2-11 / 1-13
Max pressure drop per element15 psi (0.1 MPa)

Small Water Plant And Boiler Make-Up Scenario

A community drinking water station with 2 m³/h output runs two 4040 elements in a single-stage array; the 9.3 m² area per element keeps the array compact and the 99.6% desalination rate brings product water below the local conductivity limit. In a small industrial boiler house, the same element treats make-up water so hardness and dissolved solids stay inside the boiler specification, reducing scale on heating surfaces. Food and beverage lines use it to polish process water before filling. Feed water passes a high flow filter cartridge stage first to hold SDI15 under 5.0, which is the precondition for stable membrane life.

Product Advantages

Aromatic polyamide composite construction holds a high desalination rate while the low-pressure design keeps pump energy modest compared with high-pressure elements. The 4 inch format suits small skids and containerized units where an 8040 element would need a taller vessel. Performance is specified at a defined test condition, so the quoted 2600 GPD can be checked against site temperature and pressure instead of relying on a vague claim. The element also tolerates chemical cleaning across pH 1-13, which extends service between replacements. For a complete skid, see Oil Filtration Machine.

Manufacturer And Factory Strength

Xinxiang Lifeierte Filter Corp., Ltd (Stock Code 837936) runs industrial membrane rolling, folding and trimming equipment plus an RO membrane test bench and negative-pressure inspection station, so each element is performance-checked before packing. The factory supplies RO, NF, UF and MBR lines together with the matched pretreatment filter cartridge range. For array design and recovery calculation, contact our engineering team.

FAQ

Q1: How much water does one LF-BW-4040 produce?
A1: 2600 GPD, about 9.8 m³/d, measured at 225 psi with 2000 mg/L NaCl at 25 ℃; site output varies with temperature and feed salinity.

Q2: What feed water quality does the element require?
A2: SDI15 below 5.0, free chlorine below 0.1 mg/L, temperature 0-45 ℃ and pH 2-11 during operation; pretreatment is required for surface water.

Q3: Is 4040 or 8040 the better choice for a small plant?
A3: 4040 fits compact skids and low flows; 8040 gives more area per element and is preferred above roughly 5 m³/h output.

Q4: How is the element cleaned when output drops?
A4: Chemical cleaning at pH 1-13 is permitted; record pressure drop and normalized flow before and after cleaning to judge whether replacement is due.

Q5: What is the difference between stable and minimum desalination rate?
A5: 99.6% is the typical stable value; 99.0% is the guaranteed floor used for acceptance and system design margin.

Reference: ASTM D4516 standard practice for RO performance standardization | Water Filter Element catalogue reference


{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}
{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}