Position: HOME > Product > Water purification equipment > Water Filter Element >
LF‑ULP‑8040‑D Low‑Energy 8‑Inch RO Membrane Element For Brackish Water Desalination
  • LF‑ULP‑8040‑D Low‑Energy 8‑Inch RO Membrane Element For Brackish Water Desalination
  • Single LF‑ULP‑8040‑D reverse osmosis membrane photo
  • Bulk ULP‑series ro membrane warehouse stock
  • LF‑ULP‑8040‑D ro membrane white background spiral element
  • Composite polyamide ro membrane micro close‑up

LF‑ULP‑8040‑D Low‑Energy 8‑Inch RO Membrane Element For Brackish Water Desalination

Read 1 Reviews23 Q&As Write a Review
LF‑ULP‑8040‑D low‑energy 8‑inch RO membrane element, brackish‑water reverse osmosis membrane for medium‑large industrial pure‑water making project.

PARAMETER

Brand Name:
Model Number: LF‑ULP‑4040‑D,LF‑ULP‑8040‑D,LF‑ULP‑8040‑H,LF‑ULP‑8040‑400
Nominal filtration rating:stable salt rejection 99.3%‑99.5%
Application:industrial pure‑water plant,food factory water‑making,electronics workshop water‑system
Operating pressure:
Working temperature: 5℃~45℃
Replacement or not:Replacement

Medium‑large industrial pure‑water projects need balance between water yield and desalination performance. LF‑ULP‑8040‑D ro membrane is low‑energy 8‑inch ro membrane element. This reverse osmosis membrane uses optimized composite polyamide thin‑film material, belongs to mainstream low energy ro membrane for brackish‑water treatment. This brackish water ro element achieves high salt rejection under moderate operating pressure, reduce system pump power consumption, widely used for food factory, electronic‑workshop and municipal pure‑water‑plant.


Low‑Energy RO Membrane Working Principle


Brackish raw‑water flows tangentially across surface of LF‑ULP‑8040‑D ro membrane. The composite polyamide layer of this ro membrane element realizes water molecule permeation while intercepting dissolved salt ions, silica and macromolecular organics. Permeated clean pure‑water enters central collecting tube for production usage. Concentrated brine carries intercepted pollutants and flows out of membrane housing. Smooth surface design of reverse osmosis membrane reduces organic fouling risk for this low energy ro membrane brackish water ro element.


LF‑ULP‑8040‑D low‑energy RO membrane complete spiral shot


Core Technical Parameters


  • Membrane Material: Composite polyamide for ro membrane

  • Stable Salt Rejection:99.3%‑99.5% for ro membrane element

  • Standard Test Pressure:1.03MPa for reverse osmosis membrane

  • Applicable Raw‑Water TDS:≤1500ppm brackish‑water for low energy ro membrane

  • Size Spec:8‑inch spiral wound brackish water ro element

Each LF‑ULP‑8040‑D ro membrane element passes flux‑salt‑rejection double‑inspection before delivery, fits standard 8‑inch RO pressure vessels.



Composite polyamide reverse osmosis membrane micro detail


Five Core Product Strengths


1 Energy‑Saving Moderate‑Pressure Design
Lower system power‑cost for ro membrane pure‑water‑system.

2 Stable High Salt‑Rejection Rate
Reliable desalination performance of ro membrane element for long‑time‑running.

3 Moderate Anti‑Fouling Surface
Reduce chemical‑cleaning frequency for reverse osmosis membrane.

4 Large Single‑Element Water‑Yield
Suitable for medium‑large‑capacity low energy ro membrane project.

5 Standard 8‑Inch Industry Dimension
Direct installation for existed brackish water ro element pressure‑vessel.


Application Scenarios


LF‑ULP‑8040‑D ro membrane is widely applied in industrial pure‑water plant, food‑processing factory pure‑water‑line, electronic‑workshop water‑system, brackish‑water desalination project.


Full Model List


Full Model No.Specification Introduction
LF‑ULP‑4040‑D4‑inch small‑size ro membrane, small‑scale pure‑water skid
LF‑ULP‑8040‑D8‑inch standard ro membrane element, mainstream industrial brackish‑water‑RO
LF‑ULP‑8040‑HHigh‑rejection grade reverse osmosis membrane, strict pure‑water requirement
LF‑ULP‑8040‑400Large‑membrane‑area low energy ro membrane, high water‑yield demand project

Other Related Products


LF‑U‑8040 PVDF UF Membrane Module


FAQ


Q1 What raw‑water condition fits LF‑ULP‑8040‑D ro membrane element?
A1 For brackish‑water TDS ≤1500ppm, not for high‑salinity seawater desalination.

Q2 What pre‑treatment is suggested for this ro membrane?
A2 Configure UF membrane module or pleated / melt‑blown filter cartridge as pre‑security‑filtration.

Q3 What is typical service‑life for reverse osmosis membrane?
A3 Normally 2‑3 years under qualified inlet‑water‑quality and correct chemical‑cleaning management.

Q4 Can LF‑ULP‑8040‑D replace other brand 8040‑size low energy ro membrane?
A4 Same spiral dimension, direct install in standard 8‑inch RO pressure‑vessel without modification.

Q5 When need to execute chemical cleaning for brackish water ro element?
A5 Conduct cleaning when flux drop over 15% or differential pressure obvious rising.


{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}
{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}