Position: HOME > Product > Water purification equipment > Water Filter Element >
LF-LM10 Submerged PVDF Ultrafiltration Membrane MBR Sewage Treatment
  • LF-LM10 Submerged PVDF Ultrafiltration Membrane MBR Sewage Treatment
  • Batch LF-LM10 membrane modules combined assembly
  • PVDF hollow fiber Ultrafiltration membrane micro close-up
  • LF-LM10 submerged MBR UF membrane white module
  • Single LF-LM10 hollow fiber UF membrane front shot

LF-LM10 Submerged PVDF Ultrafiltration Membrane MBR Sewage Treatment

Read 1 Reviews23 Q&As Write a Review
LEFILTER LF-LM10 UF membrane is submerged negative pressure Ultrafiltration membrane module specially for municipal sewage MBR tank pretreatment before RO membrane.

PARAMETER

Brand Name:
Model Number: LF-LM10, LF-LM15, LF-LM20
Nominal filtration rating:0.01μm hollow fiber interception precision
Application:municipal domestic sewage, printing & dyeing wastewater, industrial sewage reuse
Operating pressure:
Working temperature: 5℃ ~ 40℃
Replacement or not:Replacement

LF-LM10 submerged UF membrane is dedicated negative-pressure Ultrafiltration membrane module for biochemical MBR sewage tanks, this modified PVDF Ultrafiltration membrane is essential front protection of all kinds RO membrane element and Reverse Osmosis membrane filter. The thick tensile hollow fiber of this UF membrane module tolerates high-concentration activated sludge, fully intercept sludge flocs, bacteria and macromolecular organics which easily foul RO membrane. After treatment by Ultrafiltration membrane module, clear permeate water can directly enter Reverse Osmosis membrane element for advanced desalination. All LF-LM10 UF membrane belong to Water Filter Element series, and our oil & gas line provides full coalescer cartridge, coalescer filter cartridge, separator cartridge and natural gas filter via gas filter element.


Working Principle of LF-LM10 Ultrafiltration Membrane Module

LF-LM10 UF membrane fully submerged inside biochemical sewage tank, negative suction pressure applied inside hollow fiber cavity of this Ultrafiltration membrane. Clean water molecules penetrate 0.01μm PVDF wall to form permeate water; sludge, algae and suspended solids are trapped outside the UF membrane module. Timely aeration scrubbing and regular backwash flush accumulated dirt off Ultrafiltration membrane surface, maintain stable long-term flux to protect downstream RO membrane element and Reverse Osmosis membrane filter from frequent chemical cleaning.


LF-LM10 UF membrane module complete product shot


Standard Performance Parameters

  • Membrane Material of UF membrane module: Modified hydrophilic PVDF hollow fiber

  • Nominal Precision of Ultrafiltration membrane: 0.01μm

  • Max Transmembrane Pressure: 0.05MPa for submerged UF membrane

  • Continuous Temp: 5~40℃ matching RO membrane element

  • Downstream Matching: All XULP/BW/SW Reverse Osmosis membrane filter

Every LF-LM10 Ultrafiltration membrane module completes filament tensile and flux stability test before delivery, modular free combination fit different scale sewage MBR tanks, matched with High Flow Filter as full pre-treatment line.


PVDF hollow fiber Ultrafiltration membrane micro detail


Four Core Product Advantages

1 High Tough PVDF Filament
Thick fiber of UF membrane resists aeration scouring, ultra-low breakage rate in high sludge MBR tank.

2 Strong Oxidation Resistance
Tolerate high-concentration NaClO online cleaning to remove biofouling on Ultrafiltration membrane module.

3 Permanent Hydrophilic Property
Hard to adsorb organic sludge, reduce maintenance frequency of UF membrane system.

4 Ideal RO Pre-Treatment
Effectively cut fouling speed of RO membrane element and Reverse Osmosis membrane filter.


Main Application Fields

LF-LM10 Ultrafiltration membrane module core equipment for municipal sewage, printing dyeing wastewater zero-discharge projects, produce qualified water for subsequent RO membrane desalination. Oil & gas coalescer filter cartridge and natural gas filter check Oil & Gas Purification Equipment.


Full LF-LM Series Complete Model List

LF-LM10, LF-LM15, LF-LM20


Other Related Products

LF-XULP Ultra Low Pressure RO Membrane


FAQ About LF-LM UF Membrane Module

Q1 What operation mode does this Ultrafiltration membrane adopt?
A1 Submerged negative pressure design specially for MBR biochemical sewage tank.

Q2 Can clean UF membrane with sodium hypochlorite?
A2 Modified PVDF material bears high-strength chlorine cleaning to eliminate biofouling on Ultrafiltration membrane module.

Q3 Why use UF membrane before RO membrane element?
A1 Block colloids and algae to prevent rapid clogging of Reverse Osmosis membrane filter.

Q4 Suitable sewage type for LF-LM Ultrafiltration membrane?
A1 Municipal domestic sewage, printing & dyeing, chemical industrial wastewater reuse projects.



{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}
{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}