LEFILTER industrial RO membrane series is high efficiency Reverse Osmosis membrane element for seawater desalination, boiler feed water and industrial pure water treatment.

PARAMETER

Brand Name:
Model Number: 4040 RO, 8040 RO membrane element
Nominal filtration rating:salt rejection rate ≥99.2%
Application:seawater desalination, boiler feed water, electronic pure water, food processing water
Operating pressure:
Working temperature: 5℃ ~ 45℃
Replacement or not:Replacement

As core purification component of industrial pure water systems, water filter element RO membrane series, also named Reverse Osmosis membrane, removes salt ions, colloids, bacteria and heavy metal ions from raw water efficiently. Each standard RO membrane element adopts composite polyamide membrane layer, achieving stable high desalination rate under long continuous operation. Before entering the RO membrane module, raw water needs to be pre-filtered by high flow filter to intercept large suspended particles and extend the service life of the Reverse Osmosis membrane.

Working Principle of RO Membrane Element

Under certain operating pressure, raw water flows along the surface of the RO membrane. Pure water molecules pass through the dense membrane layer and enter the central permeate tube to form clean product water. Salt, organic matter, microorganisms and impurities cannot pass through the Reverse Osmosis membrane and flow out along the concentrated water pipeline. The spiral-wound structure of the RO membrane element enlarges filtration area per unit volume, improving water production efficiency and reducing floor space of the whole water treatment equipment.


Industrial RO membrane element complete spiral cartridge product shot


Main Technical Parameters

  • Common Sizes: 4040 RO membrane, 8040 RO membrane

  • Membrane Material: Composite polyamide thin film

  • Standard Desalination Rate: ≥99.2%

  • Max Operating Pressure: 1.6MPa

  • Operating Temperature: 5~45℃

  • Applicable Water: Seawater, brackish water, industrial circulating water

All RO membrane element products pass strict pressure resistance and salt rejection testing, widely matched with full sets of industrial water treatment water filter equipment.


Composite polyamide membrane layer detail of Reverse Osmosis membrane element


Five Core Advantages of RO Membrane Series

1 Ultra-high Desalination Efficiency
Premium polyamide Reverse Osmosis membrane stably intercept mineral salt ions for long-term running.

2 Large Water Production Capacity
Large effective filtration area of each RO membrane element improves unit water yield.

3 Anti-fouling Membrane Surface
Special hydrophilic coating of the RO membrane reduces organic dirt adhesion and easy cleaning.

4 Wide Application Compatibility
Fit seawater desalination, boiler make-up water, electroplating wastewater recovery and pharmaceutical pure water.

5 Stable Long Service Life
Resistant to mild acid and alkali cleaning liquid, extend service cycle of the Reverse Osmosis membrane.


Different size Reverse Osmosis membrane element comparison display


Typical Application Scenarios

Our industrial RO membrane element is used for seawater desalination stations, thermal power boiler feed water, electronic factory pure water, pharmaceutical preparation water and food beverage processing water. Cooperated with supporting UF membrane and high flow filter, the RO membrane forms complete multi-stage water pretreatment and deep purification solution for all industrial customers.

Related Products

Industrial Oil Purification Equipment
Gas Filter Element

FAQ About Industrial RO Membrane

Q1 What raw water pretreatment is needed before RO membrane?
A1 Equip high flow filter, UF membrane and activated carbon filter to remove large particles and colloids to protect Reverse Osmosis membrane.

Q2 What is the standard desalination rate of RO membrane element?
A2 Standard brackish water RO membrane reaches over 99.2% salt rejection rate, seawater type customized separately.

Q3 What cleaning solution can be used for fouled RO membrane?
A3 Weak acid and weak alkaline cleaning agent are allowed for periodic online cleaning of the RO membrane.

Q4 Can RO membrane work at high temperature?
A4 Long-term stable working temperature shall not exceed 45℃, high temperature will damage the Reverse Osmosis membrane layer.