Oil Purification products
Air Compressor Filter
Air Compressor Inline Filter
Water purification equipment
Air Purification Products
Brand Name: PECO‑Parker
Model Number: PS‑336
Nominal filtration rating:Gas‑phase hydrophobic separation grade
Application:Natural‑gas filter‑separator second‑stage gas‑liquid separation, matched for PCHG‑336
Operating pressure:
Working temperature: ‑29℃ ~ +116℃
Replacement or not:Replacement
Gas Filter Element provides complete paired gas‑coalescer‑separator cartridges for PECO‑Parker housing, and gas‑phase separator filter element PS‑336 is interchange hydrophobic gas‑separator cartridge for natural‑gas filter‑separator. It cannot work independently and must install behind PCHG‑336 gas‑phase coalescer. Hydrophobic media rejects liquid droplets; purified dry‑gas flows downstream. Corresponding spare‑parts belong to Interchangeable Hydraulic Filter Elements product‑catalogue.
| Cross‑reference model | PS‑336 |
| Filter media | Special hydrophobic treated synthetic media |
| Function | Gas‑phase second‑stage separation, block coalesced large liquid‑droplets, gas pass‑through |
| Outer dimension | 114.3 mm OD × 914 mm Length (36 inch) |
| Flow‑direction | Outside‑to‑inside |
| Max allowable working pressure | 10.3 MPa |
| Working medium | Raw natural‑gas, associated gas, nitrogen |
| Working temperature | -29℃ ~ +116℃ |
After PCHG‑336 coalescer converts fine aerosol into large liquid‑droplets, gas‑phase separator filter element PS‑336 acts as second‑stage barrier in filter‑separator vessel. Hydrophobic surface prevents liquid‑droplet re‑entrainment under gas‑flow impact. Liquid falls down to vessel sump for periodic draining, dry clean natural‑gas goes toward compressor and metering‑skid. Vessel assembly reference please review hydraulic filter assembly series.
Strict 1:1 dimensional match for PECO‑Parker original housing, direct drop‑in replacement. Stable hydrophobic‑performance resists high‑speed gas‑flow liquid‑re‑entrainment. Robust end‑cap construction adapts pressure fluctuation of mid‑stream natural‑gas‑pipeline. Every finished cartridge undergoes media‑surface‑hydrophobic‑performance inspection before factory‑delivery. Fit for natural‑gas transmission station bulk‑spare‑parts‑procurement.
Xinxiang Lifeierte Filter Corp.,Ltd manufactures complete‑series PECO‑Parker interchange gas‑coalescer‑separator consumables. We can deliver PCHG‑336 plus PS‑336 paired‑set one‑stop supply. For natural‑gas‑second‑stage‑separation‑technical‑consulting please contact our engineering team.
Q1:Can PS‑336 gas‑separator element be used alone without PCHG‑336 coalescer?
A1:Cannot. Gas‑separator only intercepts already enlarged liquid‑droplets; it cannot coalesce fine aerosol mist by itself. Must pair‑use with upstream gas‑phase coalescer PCHG‑336.
Q2:What failure consequence if separator media loses hydrophobic‑property?
A2:Liquid droplets are carried downstream by gas‑flow, liquid‑slug impact appears, brings compressor‑blade erosion risk and instrument malfunction.
Q3:Can PS‑336 replace liquid‑liquid separation cartridge for aviation‑fuel?
A3:No, PS‑336 is gas‑phase natural‑gas‑only separator, not for liquid‑phase jet‑fuel service.
Q4:What sealing‑material options for sour H₂S‑containing natural‑gas?
A4:Standard Buna‑N for sweet‑gas; FKM‑Viton sealing‑option for high‑H₂S sour‑gas working‑condition.
Q5:Do you supply short‑24‑inch matched separator for EZ‑PCHG‑324?
A5:Yes, matching separator model EZ‑PSFG‑324 for 24‑inch compact city‑gate‑station skid‑vessel is available.
Reference standard:API RP 1201 Recommended‑practice for natural‑gas filter‑separator
Related product:Industrial Oil Purification Equipment