Brand Name: PECO‑Parker
Model Number: PCHG‑336
Nominal filtration rating:Gas‑phase 0.3μm coalescing grade
Application:Natural‑gas gathering‑station compressor‑station filter‑separator first‑stage gas‑phase coalescing
Operating pressure:
Working temperature: ‑29℃ ~ +116℃
Replacement or not:Replacement
Gas Filter Element includes PECO‑Parker interchange gas‑phase coalescing‑separation series, and gas‑phase coalescer filter element PCHG‑336 is direct replacement for PECO‑Parker original gas coalescing cartridge. Multi‑layer gradient glass‑fiber media works under gas‑phase natural‑gas flowing‑condition. It gathers sub‑micron compressor‑oil mist and condensate aerosol into large liquid droplets. It is strictly gas‑phase element, cannot be used for liquid‑liquid aviation‑fuel coalescing application. Matching spare‑parts are inside Interchangeable Hydraulic Filter Elements product catalogue.
| Cross‑reference model | PCHG‑336 |
| Filter media | Gradient depth glass‑fiber coalescing media |
| Function | Gas‑phase coalescing: merge oil mist and hydrocarbon aerosol inside natural‑gas |
| Outer dimension | 114.3 mm OD × 914 mm Length (36 inch) |
| Flow‑direction | Outside‑to‑inside |
| Max allowable working pressure | 10.3 MPa |
| Working medium | Raw natural‑gas, associated gas, nitrogen |
| Working temperature | -29℃ ~ +116℃ |
Raw natural‑gas out of well‑head carries compressor‑lubricant‑oil mist and hydrocarbon condensate aerosol, which erode compressor blades and contaminate metering instruments. gas‑phase coalescer filter element PCHG‑336 installs as first‑stage inside vertical filter‑separator vessel at gathering‑station and compressor‑station. Tiny aerosol collides inside gradient media and agglomerates into large liquid droplets, then flows to downstream gas‑separator cartridge. Complete filter‑separator vessel reference please view hydraulic filter assembly series.
Full dimensional interchange for PECO‑Parker housing without modification. Gradient depth‑type glass‑fiber media delivers stable 0.3μm aerosol coalescing‑efficiency. Thermal‑bonded multi‑layer construction avoids fiber shedding under high‑velocity gas impact. Each cartridge passes bubble‑point test and differential‑pressure cycling‑test before delivery. Suitable for large‑volume EPC‑project spare‑parts‑procurement for mid‑stream natural‑gas‑transmission.
Xinxiang Lifeierte Filter Corp.,Ltd has dedicated gas‑phase coalescer‑separator test‑bench to simulate high‑pressure natural‑gas operating‑condition. We provide paired gas‑coalescer plus gas‑separator full‑set supply for gas‑gathering‑station and compressor‑station project. For natural‑gas‑filtration‑technical‑consulting please contact our engineering team.
Q1:What is difference between gas‑phase coalescer and liquid‑liquid coalescer?
A1:PCHG‑336 works for gas‑phase natural‑gas to coalesce oil mist and condensate aerosol; liquid‑liquid coalescer such as Z1202846 works for liquid‑phase jet‑fuel to break emulsified water droplets. They cannot cross‑use.
Q2:Does PCHG‑336 need matching gas‑separator element?
A2:Yes, paired with PS‑336 gas‑phase separator filter‑element. Coalescer grows droplets; separator blocks droplets, gas‑pass‑through.
Q3:Can PCHG‑336 handle H₂S‑containing sour natural‑gas?
A3:Standard Buna‑N seal not fit high‑H₂S sour‑gas; FKM‑Viton sealing version is available for corrosive sour‑gas condition.
Q4:How to judge replacement time for gas‑phase coalescer cartridge?
A4:Replace filter‑element when actual operating differential‑pressure reaches 25 psid recommended change‑out value.
Q5:Do you supply shorter‑length variant of PECO‑Parker gas coalescer series?
A5:Yes, EZ‑PCHG‑324 (24‑inch short‑size) is available for compact city‑gate‑station skid‑mounted vessel.
Reference standard:API RP 1201 Recommended‑practice for natural‑gas filter‑separator