Oil Purification products
Air Compressor Filter
Air Compressor Inline Filter
Water purification equipment
Air Purification Products
Brand Name: PECO‑Parker
Model Number: 95V‑MC‑48
Nominal filtration rating:Solid particulate removal grade(NO coalescing function)
Application:Natural‑gas pipeline pigging receiving‑station solid debris filtration
Operating pressure:
Working temperature: ‑29℃ ~ +121℃
Replacement or not:Replacement
Gas Filter Element supplies PECO‑Parker interchange high‑dirt‑capacity particulate gas‑filter series for pipeline maintenance station, and particulate gas filter element 95V‑MC‑48 is direct substitute for original PECO‑Parker 48‑inch long particulate gas filter cartridge. High‑capacity gradient depth‑type fiber media holds large amount of rigid solid debris produced during pigging work. Important note: this is pure solid‑particle interception filter without coalescing function, cannot handle liquid mist or aerosol droplets. It fits standard high‑dirt‑load particulate filter housing. Corresponding spare‑parts are covered within Interchangeable Hydraulic Filter Elements product‑catalogue.
| Cross‑reference model | 95V‑MC‑48 |
| Filter media | High‑dirt‑capacity gradient depth‑type glass‑fiber media |
| Function | Solid particle and debris interception only; NO coalescing / liquid aerosol separation function |
| Outer dimension | 152 mm OD × 1219 mm Length (48 inch) |
| Flow‑direction | Outside‑to‑inside |
| Max allowable working pressure | 10.3 MPa |
| Working medium | Raw natural‑gas after pipeline pigging operation |
| Working temperature | -29℃ ~ +121℃ |
During natural‑gas pipeline pigging maintenance operation, large‑quantity welding slag, rust scale and pipeline debris are stirred up and flow with natural‑gas into receiving‑station equipment. particulate gas filter element 95V‑MC‑48 installs in particulate filter housing of pigging receiving‑station. Large dirt‑holding‑capacity media captures rigid solid debris to protect downstream meters, valves and compressors. This element only filters solid particles; if liquid condensate appears in pipeline gas, independent coalescer‑separator must be installed upstream. Filter housing reference please view hydraulic filter assembly series.
Full 1:1 dimensional match for PECO‑Parker original 48‑inch particulate filter housing. Optimized gradient depth‑type media provides ultra‑high dirt‑holding‑capacity for pigging‑generated heavy solid‑debris load. Reinforced inner support skeleton resists particle impact and pressure shock. Each cartridge completes bubble‑point and differential‑pressure cycling test before factory‑delivery. Perfect choice for pipeline operator regular maintenance spare‑parts stock.
Xinxiang Lifeierte Filter Corp.,Ltd manufactures various length high‑dirt‑capacity particulate gas filter cartridges for natural‑gas pipeline station projects. We supply filter housing plus element one‑stop solution for pipeline transmission operator. For pigging‑station gas‑filtration‑technical‑consulting please contact our engineering team.
Q1:What is core function of 95V‑MC‑48 filter element?
A1:Only intercept pipeline welding slag, rust scale and solid debris generated during pigging maintenance. It does NOT have liquid coalescing or aerosol removal capability.
Q2:Can 95V‑MC‑48 replace gas‑phase coalescer cartridge for liquid mist processing?
A2:Cannot. It is purely solid‑dust‑removal particulate filter, coalescer is dedicated for merging liquid aerosol droplets; they cannot substitute each other.
Q3:Why use high‑dirt‑holding‑capacity filter for pigging receiving‑station?
A3:Pigging operation releases massive sudden solid‑debris load; large dirt‑holding capacity avoids rapid filter blocking during pigging cycle.
Q4:What replacement suggestion for filter after pigging operation?
A4:It is strongly recommended to replace filter‑element immediately after finishing pigging work regardless of differential‑pressure reading.
Q5:Do you supply shorter‑length version of 95V‑MC‑series particulate gas filter?
A5:Yes, multiple length options available upon project requirement inquiry.
Reference standard:API RP 1201 Recommended‑practice for natural‑gas filter‑separator