Oil Purification products
Air Compressor Filter
Air Compressor Inline Filter
Water purification equipment
Air Purification Products
Brand Name: 无
Model Number: LFQ-1600
Nominal filtration rating:多层砂滤(按介质级配)
Application:市政给水、工业原水预处理
Operating pressure:
Working temperature: ≤80℃
Replacement or not:Replacement
Water Filter Element pretreatment chain starts with bulk gravity filtration, and the LFQ-1600 shallow sand filter is the pressure-type multimedia unit under Water Filter Element. Working pressure 0.2-2.5 MPa, operating temperature ≤80 ℃, filtration speed 30-60 m/h, backwash water consumption 1-3%, backwash intensity 4-15 L/s·m², backwash duration 10-15 min, bed expansion 40-50%. LFQ-1600: φ1600×2200×8, DN100, single flow 100 t/h, 1.0 MPa; tank Q235B / 304 / 316L / rubber-lined carbon steel, water caps ABS / 304 / 316L.
| Model | LFQ-1600 |
| Tank size | φ1600 × 2200 × 8 mm |
| Inlet / outlet | DN100 |
| Max single flow | 100 t/h |
| Pressure | 1.0 MPa |
| Filtration speed | 30-60 m/h |
| Backwash water consumption | 1-3% |
| Backwash intensity / duration | 4-15 L/s·m² / 10-15 min |
| Bed expansion | 40-50% |
| Control mode | Manual / automatic time control |
Surface-water intakes carry seasonal silt and organic turbidity that cartridge filters cannot hold economically, and the multimedia sand filter removes bulk suspended load before cartridge or RO stages. LFQ-1600 at 100 t/h sits on a municipal make-up line or industrial raw-water station, with layered anthracite and sand media trapping silt through depth. Automatic time control sequences filter and backwash without an operator; the 1-3% backwash rate limits water waste. After sand filtration, downstream fine protection uses a High Flow Filter Cartridge or cartridge bank before membrane stages.
Pressure-type shallow-bed design keeps footprint small compared with open gravity filters, and 30-60 m/h speed suits compact stations. Layered media and ABS/304/316L water caps distribute backwash evenly to 40-50% bed expansion, preventing media channeling. Tank options Q235B, 304, 316L or rubber-lined carbon steel cover potable, process and corrosive raw water. Automatic time control reduces attendance, and single-flow range 0.5-180 m³/h scales from LFQ-400 to LFQ-1800.
Our pressure-filter workshop builds LFQ units across 400 to 1800 tank diameters, with manifold and valve trains assembled and leak-tested before dispatch. Media grading and water-cap configuration are quoted against raw-water analysis. For station layout and backwash calculation, contact our engineering team; see the matching downstream consumable line at replacement imported filter element.
Q1: What is the difference between shallow sand filter and gravity rapid sand filter?
A1: Shallow pressure beds run under pump pressure at higher speed in a compact vessel; gravity beds are open tanks with lower speed and larger footprint.
Q2: How much water does backwashing consume?
A1: 1-3% of treated flow, with 10-15 minute duration and 40-50% bed expansion, controlled automatically.
Q3: Can it remove hardness or dissolved salt?
A1: No. It removes suspended silt and turbidity; dissolved minerals need softeners or RO downstream.
Q4: Which tank material for potable water?
A1: 304 / 316L or rubber-lined carbon steel; plain Q235B is for non-potable industrial raw water.
Q5: What flow does the LFQ family cover?
A1: Single flow 0.5-180 m³/h across LFQ-400 to LFQ-1800, matching small booster stations to municipal works.
Reference: GB/T 13927 pressure filter test method for water treatment