Position: HOME > Product > Water purification equipment > Water Filter housing >
UF 2880 PVDF hollow fiber UF membrane water filter ultrafiltration membrane OEM
  • UF 2880 PVDF hollow fiber UF membrane water filter ultrafiltration membrane OEM

UF 2880 PVDF hollow fiber UF membrane water filter ultrafiltration membrane OEM

Read 1 Reviews23 Q&As Write a Review
Ultrafiltration(UF)membranesarepressure-drivenmembraneseparationtechnologiesbasedonphysicalsievingpr

PARAMETER

Brand Name:
Model Number:
Nominal filtration rating:
Application:
Operating pressure:
Working temperature:
Replacement or not:Replacement

Ultrafiltration (UF) membranes are pressure-driven membrane separation technologies based on physical sieving principles. Their core function is 

to retain colloids, bacteria, and large organic molecules while allowing water and small molecules to pass through. They are widely used in water 

treatment, food, pharmaceuticals, and environmental protection.


Water Treatment (Largest Application Area)

Municipal Water Supply: Pre-treatment at waterworks, replacing sand filtration, removing turbidity, colloids, and bacteria, improving taste and safety.

Drinking Water Purification: Household/commercial water purifiers, rural water improvement, mineral water production, retaining minerals, and removing bacteria and turbidity.

Deep Wastewater Treatment and Reuse: Core component of MBR, upgrading municipal/industrial wastewater, reclaimed water for landscaping, roads, and industrial cooling.

Industrial Pure Water/Ultrapure Water: Pre-treatment before RO in the electronics, semiconductor, and pharmaceutical industries to ensure final water quality.

Industrial Wastewater Treatment: Circulating water in printing and dyeing, papermaking, chemical, electroplating, steel, and power plants, reusing resources and achieving compliant discharge.


Model

L1

L2

L3

UF 2860

1630

1820

1860

UF 2880

2130

2320

2360

Model

UF 2860

UF 2880

Nominal membrane area

51.2 meters

77.2 meters

Nominal aperture

0.03 μm

Fiber size

ID 0.7 mm OD 1.3 mm

membrane polymers

PVDF

Application date (general purpose)

Typical filtrate flux range

40-120 liters/㎡/hour

Maximum applied feed pressure

0.6 MPa

Maximum transmembrane pressure

0.21 MPa

Maximum backwash pressure

0.25 MPa

Operating temperature range

5-45℃

pH operating range

2-12

Operation module

Filtering from the outside in

Typical process conditions

Backflushing flux

100-150 L/m²/h

Backwash duration

30-60 seconds

Reverse frequency

20-60 minutes