Position: HOME > Product > Air Compressor Inline Filter > Ultrafilter > Ultrafilter Filter >
LF‑NF‑4040 Nanofiltration Membrane Element For Ground‑Water Hardness Removal And Drinking Water Decolorization Treatment
  • LF‑NF‑4040 Nanofiltration Membrane Element For Ground‑Water Hardness Removal And Drinking Water Decolorization Treatment

LF‑NF‑4040 Nanofiltration Membrane Element For Ground‑Water Hardness Removal And Drinking Water Decolorization Treatment

Read 1 Reviews23 Q&As Write a Review
LF‑NF‑4040 4‑inch spiral‑wound nanofiltration membrane element, partial ion rejection feature, retain partial monovalent‑ion while intercepting divalent‑hard‑ion and chroma‑substance, applied for ground‑water hardness‑removal and drinking‑water decolorization project.

PARAMETER

Brand Name: Dow
Model Number: LF‑NF‑4040
Nominal filtration rating:Selective divalent‑ion rejection nanofiltration grade
Application:Ground‑water hardness‑removal and drinking‑water decolorization treatment
Operating pressure:
Working temperature: 5‑45℃
Replacement or not:Replacement

Product Overview

Water Filter Element includes nanofiltration membrane‑element special‑product‑line, and nanofiltration membrane element LF‑NF‑4040 is 4040‑size spiral‑wound nanofiltration membrane element. Nanofiltration membrane has selective separation‑characteristic: intercept divalent calcium‑magnesium hard‑ion, organic chroma‑substance, while allowing most monovalent‑sodium‑ion to pass‑through. It fits standard 4‑inch pressure‑vessel, widely used for ground‑water softening and drinking‑water decolorization. Matched pre‑security‑filter consumables belong to High Flow Filter Cartridge product‑range.

Basic Technical Parameters

ModelLF‑NF‑4040
Membrane materialComposite poly‑piperazine nanofiltration membrane
Divalent ion rejection95‑98 %
Monovalent ion rejection20‑45 %
Permeate flow2600 GPD (9.8 m³/d)
Active membrane area85 ft² (7.9 ㎡)
Max operating pressure300 psi (2.07 MPa)
Working temperature5‑45℃
PH operating range3‑10

Ground‑Water Softening And Drinking‑Water Decolorization Application Scenarios

Many rural ground‑water contains high‑calcium‑magnesium hardness and humic‑acid chroma‑substance, causing scaling and yellowish water‑color. nanofiltration membrane element LF‑NF‑4040 is installed inside nanofiltration pressure‑vessel. It removes water‑hardness and chroma‑impurity, meanwhile keeps appropriate partial‑salt‑ion in drinking‑water, different from total‑desalination of RO membrane. It is also suitable for partial‑desalination of some food‑and‑beverage process‑water. For drinking‑water‑treatment‑reference please check Industrial Oil Purification Equipment.

Core Product Advantages

Selective separation feature, remove hardness and chroma without complete removal of all mineral‑salt‑ion in raw‑water. Lower operating‑pressure compare with RO‑desalination system, save system energy‑consumption. Standard 4040 dimension fits mainstream 4‑inch pressure‑vessel. Each nanofiltration membrane‑element completes selective‑separation‑performance‑test before factory‑delivery. Suitable for small‑and‑medium‑size rural drinking‑water‑renovation‑project procurement.

Manufacturer & Factory Strength

Xinxiang Lifeierte Filter Corp.,Ltd supplies NF‑series nanofiltration, RO‑series reverse‑osmosis, UF‑series ultrafiltration membrane‑elements. We provide membrane‑element plus supporting pre‑filter consumables one‑stop‑supply for drinking‑water‑treatment‑project. For ground‑water‑softening‑project‑technical‑consulting please contact our engineering team.

FAQ

Q1:What is the biggest difference between nanofiltration membrane and RO reverse‑osmosis membrane?
A1:NF nanofiltration has selectivity: intercept divalent hard‑ion and organics, allow most monovalent‑ions pass‑through; RO membrane rejects almost all dissolved‑salt‑ion to achieve full desalination.

Q2:Can LF‑NF‑4040 completely remove total‑dissolved‑salt in ground‑water?
A2:Cannot, nanofiltration is partial‑separation, it mainly removes hardness, chroma and divalent‑salt‑ion, monovalent‑ion will remain in product‑water.

Q3:What pre‑treatment requirements for nanofiltration membrane inlet‑water?
A3:Need security‑filter pre‑filtration, remove suspended‑solids and residual‑chlorine, control feed‑water SDI value to meet membrane inlet‑requirement.

Q4:Can nanofiltration membrane replace ion‑exchange softener completely?
A4:For moderate‑hardness ground‑water it is good alternative; for ultra‑high‑hardness raw‑water need combine with other softening‑process.

Q5:Do you supply large‑size 8040 nanofiltration membrane‑element?
A5:Yes, LF‑NF‑8040 8‑inch large‑flow nanofiltration membrane‑element is available for large‑capacity water‑treatment‑skid.

Reference standard:HG/T 4135 Nanofiltration membrane element for industrial water‑treatment

Related product:hydraulic filter assembly


{sval:sql sql='SELECT n_parameter FROM dede_addonarticle WHERE aid = ~aid~ ' } {/sval:sql}