The filter elements can be fitted withmagnetic bars.
			
				Cleaning
			
				• Switch change-over valve to clean filter chamber
			
				• Release pressure in the contaminated filter chamber by means of venting screw
			
				• Lift the cover of the contaminated filter chamber
			
				• Remove filter element
			
				• Soak filter element in cleaning fluid, e.g. BOLL-CLEAN 2000, and clean with compressed air
			
				For details see operating instructions manual ”maintenance and servicing”.
			
				TECHNICAL CHARACTERISTICS
			
				• Filter housing of cast iron or ductile iron; internally nickel lined for water application
			
				• Change-over valve of cast iron; water filters rubber-lined
			
				• Optionally star-pleated  or basket
			
				 filter element, star-pleated element
			
				also available as disposable
			
				filter element
			
				• Filter fineness: 10 microns to 5 mm
			
				• Operating pressure
			
				cast iron up to 16 bars
			
				ductile iron up to 25 bars
				
				