Brand Name: None
Model Number: HEPA 610×610×150
Nominal filtration rating:99.99%(钠焰法)/ 99.9995%(MPPS)
Application:洁净室、制药、电子、特殊空调
Operating pressure:
Working temperature: 常规洁净空调工况
Replacement or not:Replacement
HEPA filtration closes the air chain after coarse and medium stages. This item sits under the medium and high efficiency filter category. Two constructions are offered: pleated HEPA with 99.99% efficiency by the sodium flame method, and clean-room terminal HEPA without pleat separator reaching 99.95%, 99.995% and 99.9995% by MPPS. The international general specification uses imported high-quality glass fiber filter paper, and the filter serves cleanrooms, special air conditioning and processing air supply.
| Nominal size | 610 × 610 × 150 mm |
| Other sizes | 305×610×150, 915×610×150, 1219×610×150 |
| Efficiency (pleated) | 99.99% (sodium flame method) |
| Efficiency (terminal) | 99.95% / 99.995% / 99.9995% (MPPS) |
| Media | Imported high-quality glass fiber paper |
| Application | Cleanroom, special HVAC, process air supply |
A solid dosage plant maintains a Grade C filling room where airborne particles must be held well below the class limit. Terminal HEPA units at 610 × 610 × 150 mm mount in the ceiling grid, and the MPPS rating of 99.9995% covers the most penetrating particle size rather than only a nominal aerosol. In electronics and food cleanrooms the pleated 99.99% version serves as the final stage behind air cleaning equipment such as pocket bag pre-filters. Replacement intervals follow room pressure and particle count trends, not a fixed calendar.
Imported glass fiber paper gives a high particle retention per unit of pressure drop, which keeps fan energy reasonable at terminal filter resistance. The pleated version with separator holds shape under high face velocity, while the separator-free terminal design gives lower weight and thinner profile for ceiling grids. Multiple MPPS grades let the user match the room class instead of over-specifying every unit, and standard metric sizes fit common grid systems.
HEPA and pocket bag filters are assembled in the same clean assembly area, with frame sealing and media integrity checked before packing. Efficiency test records can be supplied per batch for qualification files. For facilities that also operate dust collection, the group supplies baghouse dust collector units and consumables, alongside its Oil Filtration Machine line. For room class mapping and filter train selection, contact our engineering team.
Q1: What is the difference between sodium flame and MPPS efficiency?
A1: Sodium flame is a standard test method reported at 99.99%; MPPS tests at the most penetrating particle size and can reach 99.9995%.
Q2: Which grade suits a pharmaceutical filling room?
A2: Terminal HEPA at 99.995% or 99.9995% MPPS is usual; the room class and local regulation determine the exact grade.
Q3: Can HEPA filters be used without pre-filters?
A3: Not recommended; a medium stage such as F7 pocket bag filter extends HEPA life and protects it from coarse dust.
Q4: What other sizes are available?
A4: 305×610×150, 915×610×150 and 1219×610×150 mm, plus depth variants such as 610×610×292.
Q5: How is filter integrity verified at delivery?
A5: Batch efficiency records and frame seal inspection are supplied; on-site leak scan is performed after installation.
Reference: ISO 29463 high efficiency filters and filter media for removing particles from air | medium and high efficiency filter
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()